IoT Controllers · iot-controller

UC50X

Reference LoRaWAN® Version, LTE Version

Rich industrial interfaces The UC50x Series has multiple industrial interfaces to monitor and control sensors or field devices simultaneously.

  • -137 dBm @300 bpsSensitivity
  • M12 A-Coded MaleInterface type
  • 2 × GPIOPorts

Product details

Rich Industrial Interfaces

The UC50x series features multiple industrial interfaces to monitor and control field sensors or devices simultaneously.

Rich Industrial InterfacesRich Industrial InterfacesRich Industrial InterfacesRich Industrial Interfaces

SDI‑12 interface for environmental data acquisition

The UC50x series is equipped with an SDI‑12 interface, making it extremely simple to connect a wide range of instruments used for environmental monitoring. This includes weather, hydrological, agricultural, etc. sensors. With SDI‑12 support, the UC50x series extends its versatility and adaptability across multiple domains.

SDI‑12 interface for environmental data acquisition

Flexible Power Options

Solar or Battery Powered? It Depends on Your Needs.

Flexible Power Options

Ultra‑robust enclosure for harsh environments

The UC50x series is equipped with an IP68 certified enclosure and an M12 connector providing robust protection against water infiltration, corrosion, and vibrations. This combination ensures reliable long-term operation in all‑weather environments.

Note: IP68 test conditions – 1 m depth for 7 days.

Ultra‑robust enclosure for harsh environments

Real-time alerts and notifications

The UC50x series enables data threshold notifications, triggering alerts and notifications when sensor readings exceed predefined thresholds. This facilitates proactive monitoring and ensures a rapid response to abnormal situations, promoting quick resolution and preventing potential issues.

Real-time alerts and notifications

Internal and optional external antenna versions

The UC50x series offers flexibility in antenna placement, ensuring optimal signal strength and range even in environments with obstacles or difficult RF conditions.

Internal and optional external antenna versions

Analog input value conversion

The UC50x series simplifies data interpretation and usage for users by directly converting received sensor values into meaningful measurements for connected devices, eliminating the need for manual conversion.

Analog input value conversion

Modbus to LoRaWAN® converter

Modbus bridge between serial networks and Ethernet via LoRaWAN®

Modbus to LoRaWAN® converter

Typical applications

With its GPIO interface, the UC50x series can function as a pulse counter, allowing you to monitor gas, water and electricity consumption or production effortlessly.

Typical applications

NB‑IoT & CAT M versions available

Stable transmission: reliable data transmission via cellular base stations Low deployment cost: low deployment cost thanks to the presence of existing cellular base stations

Cumulative report:

Accumulates up to 12 data packets in each report to save transmission and energy consumption

Ultra‑high compatibility:

Integration with various third‑party platforms via MQTT\TCP\UDP communication.

Support for cumulative reporting for energy savings. Support for multiple network protocols to be compatible with the IoT platform

NB‑IoT & CAT M versions available

Storage capacity up to 10,000 sets of historical data records

Data can be stored on the device and cannot be deleted manually, further strengthening traceability of reported information.

LoRaWAN® version: up to 600 LTE version: 600 – 10000

Storage capacity up to 10,000 sets of historical data records

Reliable transmission support for communication

With support for data retransmission, the device guarantees that the web server receives all data even if the network is sometimes unavailable.

Milesight IoT Cloud Data Management

*Note: LoRaWAN® Only Version

Easy configuration (via NFC)

Install the Milesight ToolBox

Enable NFC and launch ToolBox, then attach your phone to the device

Check the password and start configuration

Specifications

UC50X — Specifications
SpecificationValue
LoRaWAN® version · Wireless transmission
ProtocolLoRaWAN®
AntennaInternal antenna or external antenna (hardware option) External antenna (EA) Version: 1 × 50 Ω female SMA connector
FrequencyCN470/IN865/EU868/RU864/US915/AU915/KR920/AS923-1&2&3&4
Emission Power16 dBm (868 MHz)/20 dBm (915 MHz)/19 dBm (470 MHz)
Sensitivity-137 dBm @300 bps
Operating ModeUC501 : OTAA/ABP Class A, Class C UC502 : OTAA/ABP Class A
LoRaWAN® version · Data interfaces
Interface typeM12 A-Coded Male
Version LoRaWAN® · IO
Ports2 × GPIO
Logical LevelLow: 0~0.8 V, High: 2.5~3.3 V
Maximum current20 mA
Operating ModeDigital input, digital output, pulse counter (software swappable)
Input frequencySuggested value: ≤ 4000 Hz
LoRaWAN® Version · Serial Port
Ports1 × RS232 or RS485 (software interchangeable)
Transmission Speed1200~115200 bps
ProtocolTransparent (RS232/RS485), Modbus RTU (RS485)
LoRaWAN® version · Analog input
Ports2 × Analog Input
Resolution12 bits
Input Range4~20 mA or 0~10 V (interchangeable)
LoRaWAN® Version · SDI-12
Ports1 × SDI-12
ProtocolSDI-12 V1.4, Transparent
LoRaWAN® Version · Power Output
Ports2 × 3.3 V, 2 × 5/9/12 V (interchangeable)
Power-on time before data collectionContinuo (3.3 V), 0~10 minutes (5/9/12 V)
LoRaWAN® Version · Others
Button1 × Power/Reset button (Internal)
USB1 × Type‑C (internal) for configuration and console
LED indicator1 × Restart/Reset (Indoor)
LoRaWAN® version · Software
Power on & offMobile app via NFC, PC software via USB Type-C, power button (internal)
ConfigurationMobile app via NFC, PC software via USB Type‑C, Downlink
Advanced FeatureThreshold alarm, Change alarm, Multicast (UC501 only), Data storage (600 entries), Data recoverability, Data retransmission
LoRaWAN® Version · Physical Characteristics
Power SupplyUC501 : 1. 2 × 2550 mAh Rechargeable ICR18650 Batteries 2. Embedded solar power (6V, 1.7W) 3. DC 5-24V via M12 connector UC502 : 1. 3 × 9000 mAh Replaceable ER26500 Li‑SOCl2 Batteries 2. DC 5-24V via M12 connector
Operating TemperatureUC501: -20°C~60°C UC502: -30°C~70°C
Relative humidity0 ~ 95% (Non-condensing)
Intrusion protectionIP68 (1 m underwater, 7 days)
Dimensions116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (connectors excluded)
InstallationWall or pole mounting
LoRaWAN® Version · Approvals
RegulationCE, FCC, ISED
EnvironnementRoHS
LTE Version · Wireless Transmission
AntennaInternal Antenna
Cellular bandNB‑IoT/Cat.M Version : Cat M1 : B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/B28/B66/B85 Cat NB2 : B1/B2/B3/B4/B5/B8/ B12/B13/B18/B19/B20/B25/B28/ B66/B71/B85
SIM Slot1 (Nano SIM-4FF), 1.8V
Application modeTCP/UDP/MQTT/AWS
LTE Version · Data Interfaces
Interface typeM12 A-Coded Male
LTE version · IO
Ports2 × GPIO
Logical LevelLow: 0~0.8 V, High: 2.5~3.3 V
Maximum current20 mA
Operating ModeDigital input, digital output, pulse counter (software swappable)
Input frequencySuggested value: ≤ 4000 Hz
LTE version · Serial port
Ports1 × RS232 or RS485 (software interchangeable)
Transmission Speed1200~115200 bps
ProtocolTransparent (RS232/RS485), Modbus RTU (RS485)
LTE Version · Analog Input
Ports2 × Analog Input
Resolution12 bits
Input Range4~20 mA or 0~10 V (interchangeable)
LTE Version · SDI-12
Ports1 × SDI-12
ProtocolSDI-12 V1.4, Transparent
LTE version · Power output
Ports2 × 3.3 V, 2 × 5/9/12 V (interchangeable)
Power-on time before data collectionContinuo (3.3 V), 0~10 minutes (5/9/12 V)
LTE Version · Others
Button1 × Power/Reset button (Internal)
USB1 × Type‑C (Indoor) for Console
LED indicator1 × Restart/Reset (Indoor)
LTE version · Software
Power on & offMobile app via NFC, power button (internal)
ConfigurationMobile app via NFC or Downlink
Advanced FeatureThreshold alarm, Change alarm, Cumulative report, Data storage (up to 10 000 entries), Data recoverability, Data retransmission
LTE version · Physical characteristics
Power SupplyUC501 : 1. 2 × 2550 mAh Rechargeable ICR18650 Batteries 2. Embedded solar power (6V, 1.7W) 3. DC 5-24V via M12 connector UC502 : 1. 3 × 9000 mAh Replaceable ER26500 Li‑SOCl2 Batteries 2. DC 5-24V via M12 connector
Operating TemperatureUC501: -20°C~60°C UC502: -30°C~70°C
Relative humidity0 ~ 95% (Non-condensing)
Intrusion protectionIP68 (1 m underwater, 7 days)
Dimensions116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (connectors excluded)
InstallationWall or pole mounting
LTE Version · Approvals
RegulationCE

Interested in this product?

Request a quote: our team will confirm availability, compatibility and a deployment plan.

✉
WhatsAppCall usRequest a quote