IoT Controllers · iot-controller
UC50X
Reference LoRaWAN® Version, LTE Version
Rich industrial interfaces The UC50x Series has multiple industrial interfaces to monitor and control sensors or field devices simultaneously.
- -137 dBm @300 bpsSensitivity
- M12 A-Coded MaleInterface type
- 2 × GPIOPorts
Product details
Rich Industrial Interfaces
The UC50x series features multiple industrial interfaces to monitor and control field sensors or devices simultaneously.




SDI‑12 interface for environmental data acquisition
The UC50x series is equipped with an SDI‑12 interface, making it extremely simple to connect a wide range of instruments used for environmental monitoring. This includes weather, hydrological, agricultural, etc. sensors. With SDI‑12 support, the UC50x series extends its versatility and adaptability across multiple domains.

Flexible Power Options
Solar or Battery Powered? It Depends on Your Needs.

Ultra‑robust enclosure for harsh environments
The UC50x series is equipped with an IP68 certified enclosure and an M12 connector providing robust protection against water infiltration, corrosion, and vibrations. This combination ensures reliable long-term operation in all‑weather environments.
Note: IP68 test conditions – 1 m depth for 7 days.

Real-time alerts and notifications
The UC50x series enables data threshold notifications, triggering alerts and notifications when sensor readings exceed predefined thresholds. This facilitates proactive monitoring and ensures a rapid response to abnormal situations, promoting quick resolution and preventing potential issues.

Internal and optional external antenna versions
The UC50x series offers flexibility in antenna placement, ensuring optimal signal strength and range even in environments with obstacles or difficult RF conditions.

Analog input value conversion
The UC50x series simplifies data interpretation and usage for users by directly converting received sensor values into meaningful measurements for connected devices, eliminating the need for manual conversion.

Modbus to LoRaWAN® converter
Modbus bridge between serial networks and Ethernet via LoRaWAN®

Typical applications
With its GPIO interface, the UC50x series can function as a pulse counter, allowing you to monitor gas, water and electricity consumption or production effortlessly.

NB‑IoT & CAT M versions available
Stable transmission: reliable data transmission via cellular base stations Low deployment cost: low deployment cost thanks to the presence of existing cellular base stations
Cumulative report:
Accumulates up to 12 data packets in each report to save transmission and energy consumption
Ultra‑high compatibility:
Integration with various third‑party platforms via MQTT\TCP\UDP communication.
Support for cumulative reporting for energy savings. Support for multiple network protocols to be compatible with the IoT platform

Storage capacity up to 10,000 sets of historical data records
Data can be stored on the device and cannot be deleted manually, further strengthening traceability of reported information.
LoRaWAN® version: up to 600 LTE version: 600 – 10000

Reliable transmission support for communication
With support for data retransmission, the device guarantees that the web server receives all data even if the network is sometimes unavailable.
Milesight IoT Cloud Data Management
*Note: LoRaWAN® Only Version
Easy configuration (via NFC)
Install the Milesight ToolBox
Enable NFC and launch ToolBox, then attach your phone to the device
Check the password and start configuration
Specifications
| Specification | Value |
|---|---|
| LoRaWAN® version · Wireless transmission | |
| Protocol | LoRaWAN® |
| Antenna | Internal antenna or external antenna (hardware option) External antenna (EA) Version: 1 × 50 Ω female SMA connector |
| Frequency | CN470/IN865/EU868/RU864/US915/AU915/KR920/AS923-1&2&3&4 |
| Emission Power | 16 dBm (868 MHz)/20 dBm (915 MHz)/19 dBm (470 MHz) |
| Sensitivity | -137 dBm @300 bps |
| Operating Mode | UC501 : OTAA/ABP Class A, Class C UC502 : OTAA/ABP Class A |
| LoRaWAN® version · Data interfaces | |
| Interface type | M12 A-Coded Male |
| Version LoRaWAN® · IO | |
| Ports | 2 × GPIO |
| Logical Level | Low: 0~0.8 V, High: 2.5~3.3 V |
| Maximum current | 20 mA |
| Operating Mode | Digital input, digital output, pulse counter (software swappable) |
| Input frequency | Suggested value: ≤ 4000 Hz |
| LoRaWAN® Version · Serial Port | |
| Ports | 1 × RS232 or RS485 (software interchangeable) |
| Transmission Speed | 1200~115200 bps |
| Protocol | Transparent (RS232/RS485), Modbus RTU (RS485) |
| LoRaWAN® version · Analog input | |
| Ports | 2 × Analog Input |
| Resolution | 12 bits |
| Input Range | 4~20 mA or 0~10 V (interchangeable) |
| LoRaWAN® Version · SDI-12 | |
| Ports | 1 × SDI-12 |
| Protocol | SDI-12 V1.4, Transparent |
| LoRaWAN® Version · Power Output | |
| Ports | 2 × 3.3 V, 2 × 5/9/12 V (interchangeable) |
| Power-on time before data collection | Continuo (3.3 V), 0~10 minutes (5/9/12 V) |
| LoRaWAN® Version · Others | |
| Button | 1 × Power/Reset button (Internal) |
| USB | 1 × Type‑C (internal) for configuration and console |
| LED indicator | 1 × Restart/Reset (Indoor) |
| LoRaWAN® version · Software | |
| Power on & off | Mobile app via NFC, PC software via USB Type-C, power button (internal) |
| Configuration | Mobile app via NFC, PC software via USB Type‑C, Downlink |
| Advanced Feature | Threshold alarm, Change alarm, Multicast (UC501 only), Data storage (600 entries), Data recoverability, Data retransmission |
| LoRaWAN® Version · Physical Characteristics | |
| Power Supply | UC501 : 1. 2 × 2550 mAh Rechargeable ICR18650 Batteries 2. Embedded solar power (6V, 1.7W) 3. DC 5-24V via M12 connector UC502 : 1. 3 × 9000 mAh Replaceable ER26500 Li‑SOCl2 Batteries 2. DC 5-24V via M12 connector |
| Operating Temperature | UC501: -20°C~60°C UC502: -30°C~70°C |
| Relative humidity | 0 ~ 95% (Non-condensing) |
| Intrusion protection | IP68 (1 m underwater, 7 days) |
| Dimensions | 116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (connectors excluded) |
| Installation | Wall or pole mounting |
| LoRaWAN® Version · Approvals | |
| Regulation | CE, FCC, ISED |
| Environnement | RoHS |
| LTE Version · Wireless Transmission | |
| Antenna | Internal Antenna |
| Cellular band | NB‑IoT/Cat.M Version : Cat M1 : B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/B28/B66/B85 Cat NB2 : B1/B2/B3/B4/B5/B8/ B12/B13/B18/B19/B20/B25/B28/ B66/B71/B85 |
| SIM Slot | 1 (Nano SIM-4FF), 1.8V |
| Application mode | TCP/UDP/MQTT/AWS |
| LTE Version · Data Interfaces | |
| Interface type | M12 A-Coded Male |
| LTE version · IO | |
| Ports | 2 × GPIO |
| Logical Level | Low: 0~0.8 V, High: 2.5~3.3 V |
| Maximum current | 20 mA |
| Operating Mode | Digital input, digital output, pulse counter (software swappable) |
| Input frequency | Suggested value: ≤ 4000 Hz |
| LTE version · Serial port | |
| Ports | 1 × RS232 or RS485 (software interchangeable) |
| Transmission Speed | 1200~115200 bps |
| Protocol | Transparent (RS232/RS485), Modbus RTU (RS485) |
| LTE Version · Analog Input | |
| Ports | 2 × Analog Input |
| Resolution | 12 bits |
| Input Range | 4~20 mA or 0~10 V (interchangeable) |
| LTE Version · SDI-12 | |
| Ports | 1 × SDI-12 |
| Protocol | SDI-12 V1.4, Transparent |
| LTE version · Power output | |
| Ports | 2 × 3.3 V, 2 × 5/9/12 V (interchangeable) |
| Power-on time before data collection | Continuo (3.3 V), 0~10 minutes (5/9/12 V) |
| LTE Version · Others | |
| Button | 1 × Power/Reset button (Internal) |
| USB | 1 × Type‑C (Indoor) for Console |
| LED indicator | 1 × Restart/Reset (Indoor) |
| LTE version · Software | |
| Power on & off | Mobile app via NFC, power button (internal) |
| Configuration | Mobile app via NFC or Downlink |
| Advanced Feature | Threshold alarm, Change alarm, Cumulative report, Data storage (up to 10 000 entries), Data recoverability, Data retransmission |
| LTE version · Physical characteristics | |
| Power Supply | UC501 : 1. 2 × 2550 mAh Rechargeable ICR18650 Batteries 2. Embedded solar power (6V, 1.7W) 3. DC 5-24V via M12 connector UC502 : 1. 3 × 9000 mAh Replaceable ER26500 Li‑SOCl2 Batteries 2. DC 5-24V via M12 connector |
| Operating Temperature | UC501: -20°C~60°C UC502: -30°C~70°C |
| Relative humidity | 0 ~ 95% (Non-condensing) |
| Intrusion protection | IP68 (1 m underwater, 7 days) |
| Dimensions | 116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (connectors excluded) |
| Installation | Wall or pole mounting |
| LTE Version · Approvals | |
| Regulation | CE |
Interested in this product?