Capteurs IoT · lorawan-sensor

CT3xx

Reference CT303, CT305, CT310

The CT3xx LoRaWAN® current sensor enables wireless current measurement with non‑intrusive split‑core clamp installation and 300A/500A/1000A current ranges. Designed for energy trend monitoring, phase‑level sub‑metering, and equipment status detection, it simplifies current monitoring without complex wiring.

  • 3.3 kHzSampling Frequency
  • 50~60 HzWorking Frequency
  • 300 ArmsRated Primary Current (Per CT)

Specifications

CT3xx — Specifications
SpecificationValue
CT303 · Electrical Measurement
Detection ParameterRMS Current
Sampling Frequency3.3 kHz
Working Frequency50~60 Hz
Rated Primary Current (Per CT)300 Arms
Rated Secondary Current150 mArms
Minimum Reporting Current13 Arms (1 min Interval) 2.5 Arms (10 min Interval)
Accuracy±1 %
Resolution1 mA
Temperature SensorSensor type: 1 × NTC Sensor Measuring range: -20°C ~ 100°C Measuring accuracy: ±1 %
CT303 · Wireless Transmission
ProtocolLoRaWAN®
Antenna Connector1 × 50 Ω SMA Connector (Center PIN: SMA Female)
FrequencyCN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx Power16 dBm (868 MHz)/20 dBm (915 MHz)/19 dBm (470 MHz)
Sensitivity-137dBm
ModeOTAA/ABP Class A
CT303 · Others
Button1 × Reboot Button
LED Indicator1 × Status/Alarm Indicator
Port1 × USB Type-C for Power Supply, Configuration, Console or Cable Temperature Sensor Connection
CT303 · Software
ConfigurationUSB Type-C or Downlink
Advanced FeatureThreshold Alarm, Overrange Alarm, FUOTA
CT303 · Physical Characteristics
Power Supply1. Induced current power supply2 2. 5V by USB Type-C Port
Insulation Voltage3kVac(r.m.s)(1mA/1min)
Color/ MaterialBlue, PBT+PC (UL94 V0)
Cable Length1m
Operating TemperatureTransceiver: -20°C~70°C (-4°F~158°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Storage TemperatureTransceiver: -25°C~80°C (-13°F~176°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Relative Humidity≤ 95% (Non-condensing)
Ingress ProtectionIP30
DimensionsTransceiver: 38 × 34.5 × 16 mm (1.5 × 1.36 × 0.63 in) CT Clamp:56.5 × 36.5 × 68.5 mm (2.24 × 1.44 × 2.70 in) Wire Hole: Ф 24.2 mm(Ф 0.95 in)
WeightTransceiver: 13.05 g Per CT Clamp: 250 g
InstallationTransceiver: Cable-tie Mounting (under integrated mode) CT Clamp: Suspended on the Testing Conductor
CT303 · Approvals
RegulatoryCE, FCC, UL508
CT305 · Electrical Measurement
Detection ParameterRMS Current
Sampling Frequency3.3 kHz
Working Frequency50~60 Hz
Rated Primary Current (Per CT)500 Arms
Rated Secondary Current150 mArms
Minimum Reporting Current15 Arms (1 min Interval) 4.5 Arms (10 min Interval)
Accuracy±1 %
Resolution1 mA
Temperature SensorSensor type: 1 × NTC Sensor Measuring range: -20°C ~ 100°C Measuring accuracy: ±1 %
CT305 · Wireless Transmission
ProtocolLoRaWAN®
Antenna Connector1 × 50 Ω SMA Connector (Center PIN: SMA Female)
FrequencyCN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx Power16 dBm (868 MHz)/20 dBm (915 MHz)/19 dBm (470 MHz)
Sensitivity-137dBm
ModeOTAA/ABP Class A
CT305 · Others
Button1 × Reboot Button
LED Indicator1 × Status/Alarm Indicator
Port1 × USB Type-C for Power Supply, Configuration, Console or Cable Temperature Sensor Connection
CT305 · Software
ConfigurationUSB Type-C or Downlink
Advanced FeatureThreshold Alarm, Overrange Alarm, FUOTA
CT305 · Physical Characteristics
Power Supply1. Induced current power supply2 2. 5V by USB Type-C Port
Insulation Voltage3kVac(r.m.s)(1mA/1min)
Color/ MaterialBlue, PBT+PC (UL94 V0)
Cable Length1m
Operating TemperatureTransceiver: -20°C~70°C (-4°F~158°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Storage TemperatureTransceiver: -25°C~80°C (-13°F~176°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Relative Humidity≤ 95% (Non-condensing)
Ingress ProtectionIP30
DimensionsTransceiver: 38 × 34.5 × 16 mm (1.5 × 1.36 × 0.63 in) CT Clamp: 68 × 86 × 41.8 mm (2.68 × 3.39 × 1.65 in) Wire Hole: Ф 36.5 mm(Ф 1.44 in)
WeightTransceiver: 13.05 g Per CT Clamp: 276.75g
InstallationTransceiver: Cable-tie Mounting (under integrated mode) CT Clamp: Suspended on the Testing Conductor
CT305 · Approvals
RegulatoryCE, FCC, UL508
CT310 · Electrical Measurement
Detection ParameterRMS Current
Sampling Frequency3.3 kHz
Working Frequency50~60 Hz
Rated Primary Current (Per CT)1000 Arms
Rated Secondary Current150 mArms
Minimum Reporting Current110Arms (1min Interval) 8.5Arms (10min Interval)
Accuracy±1 %
Resolution1 mA
Temperature SensorSensor type: 1 × NTC Sensor Measuring range: -20°C ~ 100°C Measuring accuracy: ±1 %
CT310 · Wireless Transmission
ProtocolLoRaWAN®
Antenna Connector1 × 50 Ω SMA Connector (Center PIN: SMA Female)
FrequencyCN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx Power16 dBm (868 MHz)/20 dBm (915 MHz)/19 dBm (470 MHz)
Sensitivity-137dBm
ModeOTAA/ABP Class A
CT310 · Others
Button1 × Reboot Button
LED Indicator1 × Status/Alarm Indicator
Port1 × USB Type-C for Power Supply, Configuration, Console or Cable Temperature Sensor Connection
CT310 · Software
ConfigurationUSB Type-C or Downlink
Advanced FeatureThreshold Alarm, Overrange Alarm, FUOTA
CT310 · Physical Characteristics
Power Supply1. Induced current power supply2 2. 5V by USB Type-C Port
Insulation Voltage3kVac(r.m.s)(1mA/1min)
Color/ MaterialBlue, PBT+PC (UL94 V0)
Cable Length1m
Operating TemperatureTransceiver: -20°C~70°C (-4°F~158°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Storage TemperatureTransceiver: -25°C~80°C (-13°F~176°F) CT Clamp: -40°C~55°C (-40°F~131°F)
Relative Humidity≤ 95% (Non-condensing)
Ingress ProtectionIP30
DimensionsTransceiver: 38 × 34.5 × 16 mm (1.5 × 1.36 × 0.63 in) CT Clamp: 97.1 × 119 × 59.5 mm (3.82 × 4.69 × 2.34 in) Wire Hole: Ф 51 mm(Ф 2.01 in)
WeightTransceiver: 13.05 g Per CT Clamp: 855.55 g
InstallationTransceiver: Cable-tie Mounting (under integrated mode) CT Clamp: Suspended on the Testing Conductor
CT310 · Approvals
RegulatoryCE, FCC, UL508